Showing posts with label SPEEDNET. Show all posts
Showing posts with label SPEEDNET. Show all posts

Thursday, June 7, 2012

Updates for Speednet Virtual Scanning


Updates for Speednet Virtual Scanning


To Provide virtual scanning for all Speed Post articles including UID upto 25 days from the date of receipt of messages from Central Server, CEPT, Mysore has released exl file..


ftp://ftp.ptcinfo.org/SpeedNet/ 

Share and Care
For Latest Updates Always visit http://satish24k.blogspot.in
For Beautiful Wallpapers Always visit http://24ksatish.blogspot.in

Saturday, May 12, 2012

Speed Post Tarrif for Local and One India and One Rate


Service Tax from 01.04.2012
Speed Post Tarrif for Local and One India and One Rate

Share and Care
For Latest Updates Always visit http://satish24k.blogspot.in
For Beautiful Wallpapers Always visit http://24ksatish.blogspot.in

Monday, April 30, 2012

SpeedNet 3.1.2(15122011) Patch-3 dated 26/04/2012 :


SpeedNet_3.1.2(15122011) Patch-3 dated 26/04/2012 :

THIS PATCH IS A MUST TO BE EXECUTED AT ALL OFFICES using BNPL and Collection Agent Module.
(To update the Base Value of Speed post tariff for One India - One Rate Scheme in BNPL and CA Module)

NOTE: There is already provision in the SpeedNet Module for revising the latest Rate of the Service Tax
under the Supervisor Login:
BNPL--> BNPL Configuration --> Miscellaneous Charges --> Service Tax option.

All offices have to add the entry for new Service Tax rate of 12% effective from 01.04.2012.

This patch is released to provide the following:
1. Due to the increase in Service Tax Rate - the Base value of Speed post tariff for One India - One Rate Scheme
in BNPL is revised as follows.

Old Base Value New Base Value

Local 10.88 10.67

One India rate 22.67 22.24

2. Enhancement of Customer Agreement period from one year to two year as per BD & M Dte, N Delhi
lr.no. 57-02/2010-BD&MD dated 13.04.2012.

3. Please read the specific instructions detailed at Step III below for changes in the Collection Agent Module.

Other than BNPL Provision:

Provision is made to close FLAT RATE BOX in EPP Bags with specific Barcode prefix of "CF" for such bag.
(As per the FRB Operational Manual, separate EPP bags containing FRBs have to be closed with CF barcode only)

Flexibility is provided to close EPP Bag containing FRBs with X series/CF series barcode until it is
confirmed that all Circles have procured CF barcodes for EPP Bags containing FRBs.

Patch-3 Release for Speednet_3.1.2_15122011 release - contains 2 folders.

1. SpeedNet3.1.2_15122011_DBScript_26042012
2. SpeedNet3.1.2_15122011_ClientPatch_26042012

Pre-Requisite:


Speednet 3.1.2 should have been upgraded with the latest rlease of SpeedNet on 15/12/2011
( ftp://ftp.ptcinfo.org/SpeedNet/speednet3.1.2_15122011/)

Those who are using speednet3.1.2_15122011 but not used the Patch2, can directly upgrade with Patch3

I: Upgrade the DB first with DBscript file.

1. Take Full Backup of POSPCC DB

2. Execute the DB Script through Script Tool.exe.

3. On Successful upgradation of DB, go to Step II.

II. Now copy the Dlls, SNT and EXE:

1. Copy all the Dlls , SNT and the Exe file from the folder and copy the same
into C:\Program Files\SpeedNet folder ( default installation folder)

NOTE: There is also CollectionAgent.exe for which read step III.

2. Register all the Dlls.

3. Execute the BNPLDataCorrection.exe file which is already there in SpeedNet folder.

Now you may please run speedNet and confirm successful login.

III. For Offices having Collection Agents:


1. After doing the upgradation for Patch-3, generate Configuration File for each Collection Agent and send
it to CA for updation in his/her system.

2. Along with the Configuration file, send the latest CollectionAgent.exe file included in the Patch-3 release
and ask the CAs to overwrite the CollectionAgent.exe file in their systems
(default path: C:\Program Files\Speednet Collection Agent\).

Problems if any may please be emailed to support@ceptmysore.net with Subject as
SpeedNet Patch-3

Share and Care
 For Latest Updates Always Visithttp://satish24k.blogspot.com/

Friday, March 30, 2012

SpeedNet 3.1.2 (15122011) Patch-1 dated 28/03/2012

THIS PATCH IS A MUST TO BE EXECUTED AT ALL OFFICES WHO DO THE BNPL BILLING THROUGH SPEEDNET.

This patch is released to provide the foloiwng solutions.

1. This patch will fix the bug in BNPL Billing.

If this patch is not applied then there will be difference in the actual bill amount to
that of the Bill Amount generated in the SpeedNet from April 2012 Bill onwards.

2. Invalid Use of Null error in Receipts/Close TB/Dispatch Bags option Fixed
with a Message To fix the problem locally.


3. Error - "Data Not Saved" while Opening UID Bag is fixed

4. My Office Details - Pin Code View has been corrected for Offices whose Pin Codes are
changed.

5. SpeedNet Manifest offline printing problem solved.

6. It includes the earlier DBPatch solution -for not fetching the InsRPs from POS to SpeedNet
through Network Fetch.

SPEEDNET3.1.2_Patch1Release_28032012.zip - contains 2 folders.

1. SpeedNet3.1.2_15122011_DBScript_28032012
2. SpeedNet3.1.2_15122011_ClientPatch_28032012

Pre-Requisite:

Speednet 3.1.2 should have been upgraded with the latest rlease of SpeedNet on 15/12/2011
( ftp://ftp.ptcinfo.org/SpeedNet/speednet3.1.2_15122011/)

I: Upgrade the DB first with DBscript file.

1. Take Full Backup of POSPCC DB
2. Execute the DB Script through Script Tool.exe
3. On Successful upgradation of DB, go to Step II.

II. Now copy the Dlls and EXE:

1.Copying Dlls and Exe file into SpeedNet Client Installation Path:
------------------------------------------------------------------

2. Copy all the Dlls and the Exe file from the folder and copy the same
into C:\Program Files\SpeedNet folder ( default installation folder)

3. Register all the Dlls.

Now you may please run the speedNet and confirm the successful login.

Problems if any may please be emailed to support@ceptmysore.net with Subject as SpeedNet Patch-1 28032012.

Download

Share and Care
 For Latest Updates Always Visit http://satish24k.blogspot.com/

Thursday, February 9, 2012

SpeedNet Problems and Solutions



Trouble Shooting in SpeedNet package:
The questions /problems in this FAQ is arranged in the order of :
· Installation
· Configuration
· Login
· Supervisory options
· Operator options
· MIS
(You may also use Find option (Ctrl+F) with error description to easily locate the solution in this post)
Problem
Solution
Installation
While installing error-
“Insert Disk”
There is an old speednet CAB file present in OS installation folder.
Please search for sp*.cab file in C:\Windows or C:\Winnt folder. If found delete them.
Then install the package afresh
While installing system is asked to be restarted every time.
Check whether Service Pack SP 4 for Windows 2000 or SP3 for XP systems are installed.
While installing – error MSDART.dll file
If the following error occurs during the Client installation –
“The Procedure entry point couldn’t be located in the dynamic link library MSDART.DLL.”
When the error occurs – Click on OK.
Then next it will show a file registration error – Click on Ignore.
Then again the MSDART.DLL error occurs . Click on OK
Then next it will show another file registration error – Click on
Ignore
Now it will install.
Now package gets installed. This error will not cause any problem in the package.
Note: If any Version Conflict messages appears, then keep the existing files in the system and continue the installation.
At the end of the installation error – “Path not Found”
Click on Retry button to continue. If this doesn’t solve the problem, reinstall the client component.
Active X Component Error –
Found at any stage during installation.
Check whether Service Pack SP 4 for Windows 2000 or SP3 for XP systems are installed. Also install MDAC 2.7
If using Speednet 3.1 then download the 3.1.1 version from site.
Installation problem in Vista System for the first time
Right click on the setup.exe file and select option. This will install the package without any problem.
Also register all the dll files which are in the SpeedNet Client Installation folder.
To register the dll:
· Right click on Dll file and select Open with
· Select Browse option and go to Windows\System 32 folder. Select Regsvr32 file
· Select open and ok button in the subsequent forms.
· This will show the successful registration message.
· If this process is not registering the Dll then :- please uninstall the SpeedNet client and ensure that old installation files doesn’t exist in the system. Then go to start->Run and type msconfig. A System Tools window opens. Click on Tools option. Search for option from the list. Select it and click on Launch. Restart the system then install the SpeedNet client and then register the Dlls. At the end don’t forget to go to msconfig ->Tools and select and launch and restart system.
Note: Enable User Account Control is a must as it is a new security component in Windows Vista.
Configuration – Database Creation
While creating the database, message appears as – “Unable to load the configuration file”
Uninstall the SpeedNet Client component from Control Panel –Add Remove Programs and reinstall it.
While creating the database, “Speed Net found an illegal tampering of information... Quitting”
Uninstall the SpeedNet Client component from Control Panel –Add Remove Programs and reinstall it.
While creating database error –
“SQL Server error. Please close all applications”
This is the error related to Hard disk. Check the following.
· Drive letter provided is wrong
· POSPCC and POSPCCBackup files exist in hard disk
· No space in the hard disk.
While creating the database error – “Specified SQL Server not found”
The Server name provided is wrong. Please also check whether you have installed SQL as Instance. If so, edit the SQL Server name with SQL   Instance name.
While creating the database error “Login failed for user SA”
The SQL Password typed is wrong.
In vista – shared file is not being accessed at the end of client installation.
In cases where new systems are supplied to project arrow offices, some problems in accessing server component folder even after sharing this folder may occur due to architecture of new OS installed in these systems.
IN such case system administrator should overwrite defaults permissions given to SpeedNet server folder :
To do this they can follow the procedure below:
If it is vista operating system do the following steps before configuring the permissions:
1. Go to Start->Run and type msconfig
2. Under Tools, select Disable UAC and click on Launch button given below.
3. Restart the system.
4. Applying the permission changes to SpeedNet server folder as given below.
Permissions:
7) Right click SpeedNet Server folder, select Properties ->Security tab and click on button therein.
2) Select the user if already present in the list there or Click on Edit and then button. Type everyone and click on OK.
3) In the next screen, check on permission for Allow.
4) Click on advanced
5) Uncheck the check box . A new option screen appears wherein click on remove button
6) Now click on OK button and Ok button in the previous screen.
7) Share the SpeedNet server folder and assign full permission to user
on shared folder.
Give similar permissions to user as above.
Configuration – Other Issues
While configuring, the required SPC name is not found for selection. Then how to install?
The procedure is explained in the SpeedNet Hand Book supplied along with 3.1 version release and the copy of the same is available in Speednet 3.1 CD. (Refer 2.8)
Error Inserting Offices to OfficeMaster –Could not bulk insert. File ‘SPCMaster.txt’ does not exist
This problem is solved in Speednet 3.1.1.
You are using older version. Please download the 3.1.1 version and upgrade.
While configuring at linked office, Linked office name not found for selection. How to install?
The procedure is explained in the SpeedNet Hand Book supplied along with 3.1 version release and the copy of the same is available in Speednet 3.1 CD. (Refer 2.9)
“Automation Error” at the time of configuration
Solution 1:
Dll Registry problem. Please open the Speednet client folder path (C:\Program Files\Speednet default folder) . Register all the dll files using the regsvr32 file.
Procedure to register:
1. Right click on The dll file
2. Click on – Open with option
3. Browse – C:\Windows\System32
4. Select the file regsvr32.dll
5. Click on Ok to register.
If it is Vista System and there is problem in registration of Dll files, please see the solution given at the heading – as to how to register the dll files in vista.
While configuring Error -
"Text property read only"
This is the problem with old cab file remaining in the system during fresh installation of SpeedNet 3.1.1
Uninstall Speednet client from Add Remove programs
Search for C:\Program Files\Speednet folder ( Its default path of client folder) . If exists delete it.
Now go to search option ( or Find) of windows and search for spcl*.cab file in C:\Windows folder. If any such file exists delete it.
Then install the Speednet Client 3.1.1 afresh.
Login
While starting the package itself, there is error
“Error in Opening the Connection 70. Permission denied”
This problem would have occurred in Vista systems.
As a solution, right click on the SpeedNet exe and click on Run As Administrator option and click on Allow to run the package.
While logging in it says the user is already logged in other system.
This problem is solved in Speednet 3.1.1.
You are using older version. Please download the 3.1.1 version and upgrade.
Error while logging in –
“Not a valid Password”
This is mdb file access error through the client system.
Check the sharing permissions of the SpednetServer folder at server system. Whether the XP client user has been given full permission to access the folder.
If by giving permission if the problem is not solved, then reinstall the SpeedNet Server component and share it afresh with full permission to  
(BNPL Module – old bill data will be lost with the re installation of SpeedNet Server)
Error while login –
“BNPL Database is not found in the specified path”
This problem is solved in Speednet 3.1.1.
You are using older version. Please download the 3.1.1 version and upgrade.
Login is very slow and takes too much time.
Login as Supervisor – Use Tools->Delete Old data option. Use Truncate option to truncate the log files of POSPCC and POSPCCBackup. (Please ensure that no one uses SpeedNet at that time, else DB will be corrupt)
While Logging in Vista Systems, when selected user, given password and click on OK, package simply exists without any message or error
Right Click on the Speednet.exe which is in the SpeedNet client path (default client path is C:\Program Files\SpeedNet) and click on .
If this is not working then please share the SpeedNet Server folder in the Server System with Special Permission as given in the instruction at the heading
Shift Begin /Shift End
While making Shift End error – it gives 
BNPL Error /
Pending Message error
This problem is solved in Speednet 3.1.1.
You are using older version. Please download the 3.1.1 version and upgrade.
While making the Shift Begin – it shows the error that system date and time is incorrect.
Please check whether the System date is Current Date.
From SpeedNet 3.1 onwards , package will not allow to make the Shift Begin for a date for which already Shift Begin and Shift End are done.
While making shift End – it shows a big list of non dispatched bags.
This is not an error.
Please read the SpeedNet User Manual or for details on Non Dispatched Bag List.
While making the Shift End – Package exists automatically
Please read the SpeedNet User Manual for details on Shift End for Non Dispatched Bag List. If the list contains huge number of pending bags due to incomplete work in the package, then this happens.
Reinstallation is the solution.

***** ***** ***** ***** ***** ***** ***** ***** ***** *****
For Latest Updates Always visit http://satish24k.blogspot.in Share and Care


Monday, January 16, 2012

DOP Friends Join This Facebook Group

We have created a group in Facebook.
 
This group is exclusively meant for Postal Technological Issues, hence no personal posting please.

The main purpose of this group is to solve technological problems we are facing in DOP. Whenever you face any errors or facing difficulty in installation or updation of softwares please feel free to post your problems, we try our level best to give an earliest solution.

Please co-operate with us by adding Postal Friends to this group.



To join this group click the below given link.

SYSTEM ADMINISTRATORS DOP

As always we very much appreciate your valuable comments and suggestions.
 Share and Care
 For Latest Updates Always Visit http://satish24k.blogspot.com/

Tuesday, December 20, 2011

POS and SpeedNet MNOP Updation Script at a single point download



It is decided to keep both POS and SpeedNet MNOP Updation Script at a single point download. This script has to be used at all the offices using POS and SpeedNet.
Based on the latest Sorting Extract / Orders received from the Directorate and IC Hub Data received from Circles, the Revised MNOP Script is released and the details of the releases are as follows.
This script will contain the entire Hub Master data as per the requirement /modifications - including all the previous revisions. This document shows only the latest revisions.

Steps to Update:
Take Full Backup of POSPCC DB
Execute the EXL file through ScriptTool.exe.
Login to Speednet and check View-> Hub Details option .

Note:
SpeedNet: Script is compulsorily to be updated in concerened Hub or IC Hub as well as in all offices using SpeedNet whose Pin Code is covered under Pin Range Modification / Hub – Addition/Deletion.
At other SpeedNet offices the script may be executed so that the Hub Details option in the SpeedNet Module, will show the latest MNOP Pin Range for all hubs.
POS: All offices Booking Speed Post Articles have to update the script.


Share and Care
 For Latest Updates Always Visit http://satish24k.blogspot.com/

Friday, December 2, 2011

POS Script Speednet Script MNOP update scripts dated 30.11.2011 had been released


MNOP update scripts dated 30.11.2011 had been released.

POS Script
Speednet Script


SpeedNet: Script is compulsorily to be updated in concerened Hub or IC Hub as well as in all offices using SpeedNetwhose Pin Code is covered under Pin Range Modification / Hub – Addition/Deletion.
At other SpeedNet offices the script may be executed so that the Hub Details option in the SpeedNet Module, will show the latest MNOP Pin Range for all hubs.


POS: All offices Booking Speed Post Articles have to update the script.





Source : ftp://ftp.ptcinfo.org/
Share and Care
 For Latest Updates Always Visit http://satish24k.blogspot.com/

Thursday, November 3, 2011

Revised MNOP Script dated 01.11.2011


It is decided to keep both POS and SpeedNet MNOP Updation Script at a single point download. This script has to be used at all the offices using POS and SpeedNet. Based on the latest Sorting Extract / Orders received from the Directorate, the Revised MNOP Script is released and the details of the releases are as follows. This script will contain the entire Hub Master data as per the requirement /modifications - including all the previous revisions. This document shows only the latest revisions.


Steps to Update:
· Take Full Backup of POSPCC DB
· Execute the EXL file through ScriptTool.exe.
· Login to Speednet and check View-> Hub Details option .

Note:
SpeedNet: Script is compulsorily to be updated in all offices using SpeedNet whose Pin Code is covered under Pin Range Modification or New Office addition.
At other SpeedNet offices the script may be executed so that the Hub Details option in the SpeedNet Module, will show the latest MNOP Pin Range for all hubs.
POS: All offices Booking Speed Post Articles have to update the script.


For Latest Updates Always Visit http://satish24k.blogspot.com/

Saturday, September 3, 2011

Features of Speed Net Ver. 3.1.2 (revision) dated 30.08.2011

Speed Net Ver. 3.1.2 (revision)
Speed Net Team, Centre For Excellence In Postal Technology, PTC, Mysore is releasing an Revision Update to Speed Net Ver 3.1.2 Version with Revision Date as on 30/08/2011.
1. SpeedNet Set-Up for P2P Offices to use it along with UID Booking Module.
2. Two important solutions given as below.
A. Change in the BNPL Booking Message for Excel File Upload and Range Scan - Change in the internal process in the software. This is to fix the problem of Excel File Article Message Data getting mixed up with Range Scan Articles Message Data -when the two types of booking are executed at the same point of time from two different systems. There is possibility of missing Pin Codes due to this mixing of message data which is avoided through this updation.
B. Solution for Shift End error in SpeedNet where it is configured with No Sets.
Solution for Shift End error - "Unknown"
3. MNOP latest changes to 3 Circles AP ( Rajhamandry New IC hub) / UP ( Varanasi/Allahabad Pin Range Modification) / Punjab (Chandigarh and Patiala
Pin Range Modification). Supervisor has to use the option Master-> Hub Details and Update option to get the latest data. Latest data can be viewed thereafter.
4. Collection of counter Booked Flat Rate Box in SpeedNet with Specific Article Types. Domestic FRB as EPP / Domestic Ins FRB as Ins EPP and Foreign FRB as FRGN (Merchandise). SpeedNet will allow the prefix CF for Domestic FRBs and CP for Foreign FRBs for those types of Articles only.
5. Remarks From Other Office :- Date of Delivery can be any date between the Date of Invoice to the Current Date.
6. Discrepency Report Solution.
Other important issues provided through 23/07/2011 remains same with an additional Read me file on U series Article handling under SpeedNet Documents folder:
23/07/2011 was for providing:
i) Provisions for Prepaid/Advance Customers with Booking/Billing/Reports options.
ii) Enhanced features for Collection Agents including Billing w.r.t. acceptance of articles from Prepaid/Advance/BNPL Customers.
iii) Newly Installed and configured SpeedNet not to have BOs in Office Master - In compliance with the requirement of adding all of BOs of Pin Code Directory into SPC Site Office master data, latest BO data is available at SPC Site.
For more details, please see the New installation Notes as to how to update the latest BO data into local database.
iv) Weight Limit for Foreign EMS Articles as per Dte Lr No. 22-1/2011-DA dated 22/06/2011 is provided.
v) EPP Related : -
EPP Booking for BNPL Articles with Circle allotted Barcode prefix validation, EPP Distance Configuration for Cities, closing separate EPP Bag with EPP Articles was already provided vide release dated 20/05/2011. Delivery of EPP Articles was already available in the SpeedNet earlier version and the same is continued.
In this release we have provided – Circle Wise EPP Bag Barcode Series validation as per Dte Lr. No 10-20/2008 BD&MD dated 06/06/2011.
Please read the file - <EPP_Related_Provisions> in SpeedNet Documents folder for more details.
vi) Article/ Bag Barcode validation for Print To Post Centers who book and bag UID Articles with U series Barcodes as per Dte Lr. No. 51-53/2010-BD&MD dated 14/07/2011. Separate BO Bag Provision is made to Close BO UID Bags.
UID Booking should be done through Excel File Upload with Reference No. column filled with UID Article Reference No.
vii) Handling of U Series Barcoded UID Articles at Delivery Offices: Offices other than Print To Post Centers can receive the Bags from Print to Post Centers and receive the articles, issue to post man for delivery or send for other offices for delivery with U series Barcodes.
Please read the file - in SpeedNet Documents folder for more details.
viii) BO Bag Close with UID Bundles/Articles at Delivery Office.
When Print to Post Centers close Bags with Bundles of UID Articles to Delivery offices, there may be also Bundles for BOs of those Delivery Offices.
As those UID Bundles shouldn’t be opened at Delivery Office – BO Bag Close with UID Bundles/ Articles if any sent loose, is provided.
Please read the file - in SpeedNet Documents folder for more details
ix) MNOP Hub Master Data : Latest revisions to the Hub Master are available in this release. Supervisor has to use the option Master-> Hub Details and Update option to get the latest data. Latest data can be viewed thereafter.
Collection Agent Module:
Collection Agents using the earlier have to be provided with new Collection Agent Module provided in this folder with 18082011 date. Current SpeedNet will work only with the Collection Agent Module 18082011 - reinstalled in the Agent system.
A Summary of all New Provisions of Speednet 3.1.2 Revised version is given at the later part of this document. Please refer for more details.
Please note that – this version can also be used by all offices using SpeedNet 3.1.2 - which have not used subsequent updates of SpeedNet 3.1.2 kept in FTP site earlier to this release. However, in such offices the DB Upgradation has to be firstly done with Database Workshop Site program using the sql files available in database Upgrades folder and then use the EXL files for upgradation through ScriptTool.exe.
SpeedNet 3.1.2 – Revision 30082011 which contains the following.
New Installation Folder contains:
* SpeedNet Server 3.1 ( There is no change in this version)
* Speed Net 3.1.2 Client Setup
* SpeedNet Communication 3.1.2
* Collection Agent Booking Module Setup
* New Installation - README.Txt
SpeedNet Upgradation Folder contains:
* Database Upgrades Folder containing POSPCC and POSPCCBackup Scripts to be executed in Database Workshop For Sites Module.
(This has to be used for upgrading the 3.1.1 version to 3.1.2. and then DB Exl Scripts also have to be used to do next level upgradation.
If your office is already using the 3.1.2 but not done the subsequent upgradation - then also this step is required.)
* Database Workshop For Sites (Latest) Module to do the DB Upgradation.
* DB Exl Scripts folder contains POSPCC.Exl and POSPCCBackup.Exl files which should be run in the Script Tool.exe.
* Script Tool.Exe
* Speed Net 3.1.2 Client Setup
* Collection Agent Booking Module Setup ( Agents to be provided with new setup)
* UPDATION READ ME.TXT file to know only Upgradation procedure.
SpeedNet Documents Folder contains:
* Release_Document_of_SpeedNet_3.1.2. ( To be provided to all Operating Offices)
* Speed Net ver 3.1.2 ( Release Version) ReadMe ( This File)
* Provision of Auto Weight for Bags - Document
* EPP_Related_Provisions - Document
* Prepaid/Advance Customers Provisions - Document
* Collection Agent Provisions - Document
* Revised_Annexure1_For_DirectBag_Provision_Request - Document
* New Installation - README.txt
* UPDATION README 30082011.txt file for upgradation notes.
* Steps for - Solution_NtWorkFetch_ BNPL Exl file Upload_SQL2005.doc
* Handling UID Articles Receipt_Delivery.doc
* Deposit Bag Close and Open.doc
* Articles to be Delivered From BO.doc
__________________________________________________________________________________
For more details – read the MHT file in SpeedNet Documents Folder